◆Structure
Core | Conductor | Insulation | Inner shield | Outer shield | Jacket | O.D | |
material | Structure | ||||||
7 | Tinned copper spiral | 30AWG(25/0.05) | SRPVC or HDPE | Tinned copper spiral | Tinned copper spiral | TPU | 4.0mm |
◆Feature:all patient contact materials are latex free and have been tested according toISO10993-1, ISO10993-5 and ISO10993-10
Have Bio-compatibility and ISO13485 certification
◆Use for:adult finger clip sensor,adult soft tip sensor,aduld ear clip
single core flat 10-set wire
Core | Conductor | Insulation | Filler | Shield | Jacket | O.D | |
Material | Structure | ||||||
10 | Silvered tinsel | 4/0.23 | ------- | Kevlar | ------- | TPU | 1.4*14mm |
◆Feature:all patient contact materials are latex free and have been tested according toISO10993-1, ISO10993-5 and ISO10993-10
Have Bio-compatibility and ISO13485 certification
◆Use for:ECG monitor cable
Φ3.6 3 cores temperature cable
◆Structure:
Core | Condutor | Insulation | Inner shield | Outer shield | Jacket | OD | |
Material | structure | ||||||
3 | Bare copper | 19/0.08 | PP or HDPE | ........... | .......... | TPU | 3.6 mm |
◆Feature:all patient contact materials are latex free and have been tested according to ISO10993-1, ISO10993-5 and ISO10993-10
Have Bio-compatibility and ISO13485 certification
◆Use for:Temperature signal
19 cores PU deep gray cable
◆Structure:
Core | Conductor | Insulation | Inner shield | Outer shield | Jacket | OD | |
Material | Structure | ||||||
19 | Tinned copper | 19/0.08 | PP or HDPE | tinned copper | Braid | TPU | 7.5 mm |
◆Feature:all patient contact materials are latex free
◆Use for:Military machine
Φ4.0 4 cores ESU pencil cable
◆Structure:
core | Conductor | Insulation | Inner shield | Out shield | Jacket | OD | |
material | structure | ||||||
4 | Tinned copper | 19/0.08 | PP or HDPE | ........... | ........ | TPE | 4.0mm |
◆Feature:all patient contact materials are latex free and have been tested according to ISO10993-1,ISO10993-5 and ISO10993-10
Have Bio-compatibility and ISO13485 certification
◆Use for:ESU signal
◆Structure
core | conductor | Insulation | Inner shield | Out shield | Jacket | OD | |
material | structure | ||||||
15 | Tinned copper | 30AWG(25/0.05) | PP or HDPE | TC | Braid | TPU | 7.5 mm |
◆Feature:all patient contact materials are latex free and have been tested according toISO10993-1, ISO10993-5 and ISO10993-10
Have Bio-compatibility and ISO13485 cettification
◆Use for:Medical device
13 cores TPE jacket cable
◆Structure
core | conductor | Insulation | Inner shield | Out shield | Jacket | OD | |
material | structure | ||||||
13 | Tinned copper | 19/0.08 | PTFE | TC | TC | TPE | 8.0mm |
◆Feature:all patient contact materials are latex free have been tested according to ISO10993-1, ISO10993-5 and ISO10993-10
Have Bio-compatibility and ISO13485 certification
◆Use for:Medical device